Home > Documents > Application Notes > AMAT DPS 200mm Chamber PM

Click Here for Printer Friendly Version

Before Foamtec Logo After
BEFORE AFTER
Vacuum Chamber PM Technique
AMAT DPS 200MM Chamber Scrub
OBJECTIVE:
TO EFFECTIVELY PM THE AMAT DPS CHAMBER IN A TIMELY MANNER, WHILE SHOWING A SIGNIFICANT REDUCTION IN COST/PM BY ELIMINATING THE NEED FOR OUTSOURCED PART CLEANING VENDORS
   
Vacuum Chamber: AMAT METAL ETCH
Vacuum Chamber Process Residue: METAL ETCH DEPOSITION
Vacuum Chamber Components: DPS CHAMBER
 
Old Procedure: Remove DPS chamber from ETCH tool and replace with a clean DPS chamber. Use 15 to 20 wipes with DI water and IPA to wipe out the lower ETCH chamber and ASP chamber
Recovery time: 4 to 6 hours

PROBLEM: DPS CHAMBER SENT TO OFF SITE TO BE CLEANED BY OUTSOURCED PARTS CLEANING VENDOR

New Procedure: Remove DPS chamber from ETCH tool and replace with a clean DPS chamber. Use 15 to 20 wipes with DI water and IPA to wipe out the lower ETCH chamber and ASP chamber
Recovery time: 4 to 6 hours
SOLUTION: DPS CHAMBER EASILY CLEANED ON SITE BY CUSTOMER USING FOAMTEC INTERNATIONAL’S PM TECHNIQUE SAVING LARGE COSTS
 
Foamtec Products
Vacuum Chamber Products:
AMAT DPS 200MM CHAMBER PM KIT
PM Kit P/N: HT4500 – AMTDPS2
(2) HT4754 UltraSOLV® Sponge
(2) HT4580D-10  800 Grit Diamond ScrubPAD
(1) HT179080D-1  800 Grit Diamond ScrubTIP®
(2) HT5790S-5 MiraWIPE® Wipers (10pc)
(2) HT1501FC-5 MiraSWAB®Swabs (10pc)
 
AMAT DPS 200MM Chamber Scrub PM Procedure:
 
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
 
Step 1:

Using proper procedures and safety guidelines remove AMAT DPS Chamber from ETCH tool and stage for proper wet clean

 
Step 2:

If needed, use an approved fab vacuum and vacuum out the DPS Chamber to remove excessive flakes prior to performing wet clean

 
Step 3: Fill a small container with 1/3 full of DI water and stage next to DPS Chamber (See Fig 1)
 
Staged cleaning products  
Fig 1:  Foamtec International products staged for source chamber clean
 
Step 4: Place HT4754 UltraSOLV® Sponge in container of DI water to moisten sponge
 
Step 5: Using the dampened UltraSOLV® Sponge, begin wiping off deposition from the DPS Chamber walls (See Fig 2 & 3)
 
Dampen sponge prior to wiping       Build-up removed from DPS Chamber
Fig 2 & 3: Dampened UltraSOLV® Sponge wiping off deposition from DPS Chamber
 
 
Step 6: It is important to keep rinsing off the UltraSOLV® Sponge with DI water in order to help clear the sponge free from deposition (See Fig 4 & 5)
 
Bucket of DI water for rinsing       UltraSOLV sponge after being rinsed
Fig 4 & 5:  Rinsing off the UltraSOLV® Sponge in DI water
 
 
Step 7: Continue wiping the DPS chamber with the dampened UltraSOLV® Sponge and rinsing off the sponge as necessary.  It is important to keep the UltraSOLV Sponge moist as the DI water will react with the deposition on the DPS Chamber making it easier to remove
 
Step 8: Continue wiping the DPS Chamber for 30 to 45 minutes or until all of the heavier deposition throughout the chamber has been removed
 
Step 9: Pour the contaminated DI water in properly approved drain and refill the container with fresh DI water
 
Step 10: Place the 2nd UltraSOLV® Sponge and one of the 800 Grit Diamond ScrubPADS into the container of DI water (See Fig 6)
 
   
Place UltaSOLV sponge and ScrubPAD in fresh DI water
Fig 6: Placing UltraSOLV® Sponge and Diamond Grit ScrubPAD in fresh DI water
 
 
Step 11: In order to fully remove the remaining deposition accumulated on the DPS Chamber, take the dampened 800 Grit Diamond ScrubPAD and begin scrubbing the chamber walls (See Fig 7)
 
 
Diamond ScrubPAD removing remaining build-up
 
 
Fig 7:  Diamond ScrubPAD scrubbing off remaining deposition from DPS Chamber
 
 
 
Step 12: As the deposition begins to loosen on the chamber walls, take the dampened UltraSOLV® sponge and wipe of the loose deposition
 
 
UltraSOLV sponge removing loose deposition
 
Fig 8:  UltraSOLV® Sponge removing loose deposition from DPS Chamber
 
 
 
Step 13: As the ScrubPAD loads up with deposition, pull across dampened UltraSOLV® Sponge to unload ScrubPAD (See Fig 9, 10 & 11)
 
ScrubPAD loaded with deposition
Pull ScrubPAD across UltraSOLV Sponge
Unloaded ScrubPAD
   
Fig 5: ScrubPAD loaded with deposition
 
Fig 6: Pull ScrubPAD across UltraSOLV® Sponge
 
Fig 7: Unloaded ScrubPAD
 
Step 14: As UltraSOLV® Sponge becomes loaded with deposition, rinse in container of DI water (See Fig 12 & 13)
 
Loaded UltraSOLV Sponge
UltraSOLV after rinse
Fig 3: Loaded-up UltraSOLV® Sponge
Fig 4: UltraSOLV® Sponge AFTER rinse
 
Step 15: Repeat steps 11 - 14, scrubbing the remaining areas of the DPS Chamber, ensuring to rinse out UltraSOLV® Sponge and unload 800 Grit Diamond ScrubPAD as necessary
 
Step 16: After 20 – 30 minutes of scrubbing, take the 2nd 800 Grit Diamond ScrubPAD and using the same technique described above, scrub the remaining areas of the DPS Chamber concentrating on the areas where heavy buildup may have accumulated (See Fig 14)
 
 
ScrubPAD Scrubbing Beamline
   
Fig 14: Scrubbing remaining deposition from DPS Chamber
 
 
Step 17: Ensure to remove the corner access plates around the DPS Chamber (See Fig 15)
 
Removing access plates
 
 
Fig 15: Removing access plates around DPS Chamber
 
 
 
Step 18: In order to effectively reach into the holes around the DPS Chamber, roll up the 800 Grit Diamond ScrubPAD.  Insert the rolled up ScrubPAD and continue to twist while pulling the ScrubPAD in and out of the hole.  This will help remove the accumulated deposition from within the holes (See Fig 16)
 
 
Rolled ScrubPAD removing build-up from holes
   
 
Fig 16:  Rolled up Diamond ScrubPAD removing deposition from holes throughout DPS Chamber
 
 
 
Step 19: If there is still some remaining deposition accumulated in any of the holes, take the 800 Grit Diamond ScrubTIP® and insert into the holes and scrub deposition free (See Fig 17)
 
ScrubTIP used to scrub build-up from within holes on DPS
 
  Fig 17:  800 Grit Diamond ScrubTIP® used to scrub out deposition from within holes throughout DPS  
 
 
Step 20: In preparation for DPS Chamber Final Wipe, take an HT5790S MiraWIPE® and saturate with DI water
 
Step 21: With DI water saturated MiraWIPE® proceed to wipe down the entire DPS Chamber, that includes all areas throughout the chamber walls and all areas outside of the DPS Chamber, including top and bottom of DPS Chamber (See Fig 18 & 19)
 
MiraWIPE saturated  with DI water
     
MiraWIPE wiping down entire DPS Chamber
Fig 18 & 19:  DI water saturated MiraWIPE® wiping down entire DPS Chamber
 
 
Step 22: Take a second MiraWIPE® and saturate with IPA and repeat step 21 using the IPA saturated MiraWIPE®
 
FINAL WIPE PROCEDURE:
 
IMPORTANT NOTE
THE USE OF HT5790S MiraWIPES® DURING FINAL WIPE PORTION OF PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVING PARTICLE DEFECTS FROM THE DPS CHAMBER
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 10a & 10b)
 
MiraWIPES are more effective
Fig 10a: Current fab wiper after completely wiping the chamber
Fig 10b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
 
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
 
Step 23: As a good standard practice, ensure to replace gloves with a new set prior to performing final wipe procedure
 
Step 24: Saturate the HT5790S MiraWIPE® with IPA and proceed to wipe out all areas of the DPS Chamber
 
Step 25: Using the HT1511FC MiraSWABS® saturated with IPA effectively wipe out all the hard to reach areas, including all o-ring areas throughout the DPS Chamber (See Fig 21)
 
    MiraSWAB wiping o-ring area
 

Fig 21:  MiraSWAB® wiping out o-ring area of DPS Chamber

 
 
 
Step 26: If bake oven is available and time allows, place DPS Chamber in oven for 4 to 6 hours prior to placing back into AMAT Centura ETCH tool
 
Before
After
 
Before
After
 
Before
After
BEFORE AFTER