OBJECTIVE:
TO EFFECTIVELY PM THE AMAT QUANTUM X PROCESS CHAMBER IN A TIMELY MANNER, WHILE IMPROVING TOOL RECOVERY AND PARTICLE PERFORMANCE
 
Vacuum Chamber: AMAT QUANTUM–X™ IMPLANTER
Vacuum Chamber Process Residue: PROCESS INDUCED RESIDUE
Vacuum Chamber Components: PROCESS CHAMBER & DECEL COLUMN
Old Procedure:

4+ hours using Scotch-Brite™ with 200+ wipes

Tool recovery: 6 to 8 Hours conditioning wafers to pass particle specs
New Procedure:

<2 hour using 360 Grit Diamond ScrubPAD, UltraSOLV® Sponge, DI water & IPA with 25 MiraWIPES®

Tool recovery: <4 Hours CONDITIONING WAFERS TO PASS PARTICLE SPECS
Foamtec products
Vacuum Chamber Products:
AMAT Quantum–X™ PM Kit
PM Kit P/N: HT4500 - QUAN4
(2) HT4536D-10-1 360 Grit Diamond ScrubPAD
(1) HT4528D82-1  280 Grit Diamond ScrubPAD For ErgoWRENCH®
(1) HT4754 UltraSOLV® Sponge
(4) HT1511FC-5 MiraSWABS® (20 MiraSWABS®)
(1) HT5790S-25 MiraWIPES®  (25 MiraWIPES®)
(1) HT4790-5 UltraSOLV® Wipers
Implant AMAT Quantum–X™ Process Chamber PM Procedure:
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines properly prepare AMAT Quantum–X™ process chamber for wet clean
Step 2: Fill FT1301 plastic container with approximately 12oz of DI water and place on protective pad next to process chamber (See Fig 1)
FT1301 with DI water
Fig 1:  FT1301 plastic container with DI water
Step 3: Place HT4536D 360 Grit Diamond ScrubPAD and HT4754 UltraSOLV® Sponge in container of DI water to moisten products
Step 4: Take lightly dampened UltraSOLV® Sponge and wipe area of process chamber and decel column to be cleaned
Step 5: Take lightly dampened 360 Grit Diamond ScrubPAD and proceed to scrub off deposition from Decel Column (See Fig 2 & 3)
Slightly dampened ScrubPAD
ScrubPAD scrubbing Decel Column
Fig 2 & 3:  Lightly dampened 360 Grit Diamond ScrubPAD scrubbing areas within Decel Column

Fig 3b:  UltraSOLV® Sponge placed at bottom of bushing to collect any excess water

NOTE: WHEN SCRUBBING AREA ABOVE DECEL COLUMN, RECOMMEND PLACING UltraSOLV® SPONGE AT BOTTOM OF BUSHING TO ABSORB ANY EXCESS WATER DRAINING FROM THE 360 GRIT DIAMOND ScrubPAD (See Fig 3b)
Step 6: After scrubbing a small area with the 360 Grit Diamond ScrubPAD, take the lightly dampened UltraSOLV® Sponge and wipe deposition from the scrubbed area (See Fig 4)
Dampened Sponge wiping build-up
Fig 4:  Lightly dampened UltraSOLV® Sponge wiping deposition from process chamber
Step 7: As Diamond ScrubPAD loads-up with deposition, pull ScrubPAD across damp UltraSOLV® Sponge to properly unload (See Fig 5, 6 & 7)
 
Loaded ScrubPAD
Pull ScrubPAD across UltraSOLV Sponge
Unloaded ScrubPAD
Fig 5: ScrubPAD loaded with deposition
Fig 6: Pull ScrubPAD across UltraSOLV® Sponge
Fig 7: Unloaded ScrubPAD
 
Step 8: Unload UltraSOLV® Sponge as much as possible by placing it back in container of DI water, and RINSE-OUT thoroughly (See Fig 8 & 9)
Loaded UltraSOLV Sponge
UltraSOLV after rinse
Fig 8: Loaded-up UltraSOLV® Sponge
Fig 9: UltraSOLV® Sponge AFTER rinse
Step 9: For areas of heavy deposition build-up, attach a 280 Grit Diamond HT4528D82-1 ScrubPAD to a FT832 ErgoWRENCH® and using the same technique outlined above scrub deposition from those areas (See Fig 10)
      Scrubbing heavy deposition build-up  
 
Fig 10: ErgoWRENCH® scrubbing heavy deposition build-up
 
         
Step 10: Repeat steps 4 – 9 for all remaining areas throughout Quantum X Process Chamber
Step 11: When scrub portion of wet clean is complete, prepare chamber for FINAL WIPE PROCEDURE by rinsing out UltraSOLV® Sponge with fresh DI water and perform a complete final process chamber wipe using the dampened UltraSOLV® Sponge
Step 12: Take clean N2 or He and blow out all tight areas and corners where DI water may have accumulated during the wet clean, ensure to have a wiper next to the area being blown in order to catch any spraying water that might be dispersed  (See Fig 11 & 12)
Clean helium blowing out tight corners that may have accumulated water
Clean helium blowing out tight corners that may have accumulated water
 
  Fig 11 & 12: Clean He blowing out the tight corners where DI water may have accumulated  
 
 
FINAL WIPE PROCEDURE:
IMPORTANT NOTE

MUST USE HT5790S MiraWIPES® AND HT1511FC MiraSWABS® DURING FINAL WIPE PORTION OF PROCEDURE TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM QUANTUM X PROCESS CHAMBER

 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 13a & 13b)
MiraWIPES are more effective
Fig 13a: Current fab wiper after completely wiping the chamber
Fig 13b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
 
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
NOTE: Below is an example of the particles left behind in the Quantum X Decel Column after the FINAL WIPE PORTION of the PM was performed with current fab wiper (See Fig 14)
Particles picked up with MiraWIPE after wiping with fab wiper
 
 
Fig 14: Particles picked up using HT5790S  MiraWIPE® after completely wiping with current fab wiper
 
 
Step 13: After scrubbing Quantum X Process Chamber, remove and replace your gloves with a clean pair of gloves
 
Step 14: Fold the HT5790S MiraWIPE® into quarters and dampen with IPA
 
Step 15: With the dampened MiraWIPE®, wipe down all areas of the process chamber.  Refold the MiraWIPE® as necessary to expose a clean side of the MiraWIPE® as you wipe all areas of the chamber (See Fig 15 & 16)
Wiping with MiraWIPE
Wiping with MiraWIPE
 
 
Fig 15 & 16: HT5790S MiraWIPE® effectively wiping all areas throughout process chamber
 
 
NOTE: REPLACE WITH A NEW DAMPENED MiraWIPE® AS NECESSARY
Step 16: Dampen the HT1511FC MiraSWAB® with IPA and wipe out the hard to reach areas, such as o-ring grooves, screw holes and tight corners (See Fig 17 & 18)
MiraSWAB wiping grooves of process chamber
 
Wiping with MiraSWAB
 
Fig 17 & 18: HT1511FC MiraSWAB® effectively wiping tight areas throughout process chamber
 
 
NOTE: Below is an example of the particles the HT1511FC MiraSWAB® was able to remove from the hard to reach, tight areas in the Quantum X Decel Column (See Fig 19 & 20)
MiraSWABS® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
 
 
Additional build-up easily removed   Excess contamination
 
Fig 19 & 20: Additional contamination the HT1511FC MiraSWAB® effectively removed from Quantum X Decel Column
 
 
 
Step 17:

Repeat above MiraWIPE® & MiraSWAB® FINAL WIPE PROCEDURE on all remaining areas of Quantum X process chamber and associated parts

 
Step 18:

Wipe down all bead blasted parts with IPA and HT4790 UltraSOLV® wipers. Wipe all non-bead blasted parts going back into the process chamber with HT5790S MiraWIPES® and IPA (See Fig 21)

 
 
Particles our Wiper picked up from supposedly clean bead-blasted part
 
 
Fig 21: Particles the UltraSOLV® Foam wiper was able to remove from a supposed clean bead-blasted part
 
 
 
Step 19: Using proper procedures and safety guidelines return Quantum X Process Chamber to production
 