Home > Documents > Application Notes > Implant Viista 80
Click Here for Printer Friendly Version
Before
Foamtec Logo
After
BEFORE AFTER
Vacuum Chamber PM Technique
Implant Varian VIISta 80 Beamline Clean
OBJECTIVE:
TO PM THE VARIAN VIISta 80 BEAMLINE IN AN EFFECTIVE AND TIMELY MANNER WHILE IMPROVING PARTICLE PERFORMANCE, TOOL RECOVERY AND MAXIMIZING TOOL UPTIME
 
Vacuum Chamber: VARIAN VIISTA 80 HIGH CURRENT
Vacuum Chamber Process Residue: PROCESS INDUCED RESIDUE
Vacuum Chamber Components: BEAMLINE CHAMBER
Old Procedure: 2 hours, H2O2, Scotch-Brite™, DI water 100+ wipes and IPA
Recovery time: 4 to 6 hours
New Procedure: 1 HOUR, Foamtec PM Kit with DI water
Recovery time: 1 to 2 hours
DANGER:
USE OF HYDROGEN PEROXIDE (H2O2) CAUSES A VARIETY OF ENVIRONMENTAL, HEALTH, AND SAFETY CONCERNS. CAN CAUSE PROLONGED PUMP DOWN TIMES AND HIGH VOLTAGE ARCING. BREATHING APPARATUS AND FULL ACID PPE IS RECOMMENDED WHILE SCRUBBING WITH H2O2. SCRUBBING PHOSPHORUS WHILE USING H2O2 INCREASES THE RISK OF FIRES AND/OR THE RELEASE OF HAZARDOUS CHEMICAL FUMES, POTENTIALLY RESULTING IN PERSONAL INJURY AND PROPERTY DAMAGE.
Foamtec Products
Vacuum Chamber Products:
PM Kit P/N: HT4500 – VAR2 PM KIT
(1) HT4754 UltraSOLV® Sponge
(1) HT4536DC3-1 360 Grit Diamond ScrubDISK®
(1) HT4528D-10-1 280 Grit Diamond ScrubPAD
(1) FT901 ErgoSCRUB® w/hook
(2) HT5790S-5 MiraWIPES®
Varian VIISta 80 Beamline Clean PM Procedure:
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines, properly prepare Varian VIISta 80 Beamline chamber for wet clean
Step 2: Stage a small container of DI water inside a large plastic bag next to VIISta 80 Beamline
Step 3: Attach HT4536DC3-1 360 Grit Diamond ScrubDISK® onto FT901 Soft ErgoScrub®
Step 4: Place HT4754 UltraSOLV® Sponge, ErgoSCRUB® w/ScrubDISK® and ScrubPAD in container of DI water to moisten products (See Fig 1)
Foamtec Products
Fig 1: Foamtec International products in small container of DI water
Step 5: Take dampened UltraSOLV® Sponge and wipe out Beamline, removing any loose deposition or flakes. Continue to re-moisten the UltraSOLV® Sponge in container of DI water as necessary
Step 6: Take dampened 360 Grit Diamond ScrubDISK® attached to ErgoSCRUB® and scrub areas throughout the VIISta 80 Beamline
Step 7: As loose deposition begins to build up within the Beamline, take UltraSOLV® Sponge and wipe the area free of deposition (See Fig 2)
UltraSOLV Sponge wiping out deposition
Fig 2: UltraSOLV® Sponge used to wipe out loosened deposition
Step 8: Continue to rinse out sponge in container of DI water as necessary to free UltraSOLV® Sponge of excess deposition as necessary (See Fig 3 & 4)
Loaded UltraSOLV Sponge
UltraSOLV after rinse
Fig 3: Loaded-up UltraSOLV® Sponge
Fig 4: UltraSOLV® Sponge AFTER rinse
Step 9: As ScrubDISK® loads up with deposition, pull & twist ScrubDISK® across UltraSOLV® Sponge to unload ScrubDISK® (See Fig 5, 6 & 7)
Loaded ScrubDISK
Pull ScrubDISK across Sponge
Unloaded ScrubDISK
Fig 5: ScrubDISK® loaded with deposition
Fig 6: Pull and Twist ScrubDISK® across UltraSOLV® Sponge
Fig 7: Unloaded ScrubDISK®
Step 10: Repeat steps 6 – 9, scrubbing the remaining areas of the VIISta 80 Beamline as much as possible. Ensure to rinse out UltraSOLV® Sponge and unload 360 Grit Diamond ScrubDISK® as necessary
Step 11: Moisten 280 Grit Diamond ScrubPAD in container of DI water and re-scrub all areas of the VIISta 80 Beamline using the same technique described above, concentrating on the areas of heavier deposition buildup and hard to reach areas throughout the Beamline (See Fig 8)
ScrubPAD Scrubbing Beamline

Fig 8: 280 Grit Diamond ScrubPAD scrubbing Beamline

Step 12: When deposition has been sufficiently removed throughout the entire VIISta 80 Beamline, rinse out UltraSOLV® Sponge with fresh DI water and re-wipe the entire VIISta 80 Beamline in preparation for FINAL WIPE PROCEDURE (See Fig 9)
Beamline after scrub
Fig 9: VIISta 80 Beamline after scrub portion of PM
FINAL WIPE PROCEDURE:
IMPORTANT NOTE
THE USE OF HT5790S MiraWIPES® DURING FINAL WIPE PORTION OF PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVING PARTICLE DEFECTS FROM VARIAN VIISta 80 BEAMLINE
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 10a & 10b)
MiraWIPES are more effective
Fig 10a: Current fab wiper after completely wiping the chamber
Fig 10b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Step 13: Dampen the HT5790S MiraWIPES® with IPA and perform a THOROUGH AND EFFECTIVE FINAL WIPE-DOWN of the entire VIISta 80 Beamline – including o-ring grooves and all vacuum sealing surfaces
Step 14: Ensure to wipe down all shields and spare parts and place back into the Beamline using additional dampened HT5790S MiraWIPES®
Beamline chamber before Beamline chamber before
Recommend removing all subassemblies to prevent any loose deposition from accumulating in o-ring grooves or leach-check ports
VIISta 80 BEAMLINE CHAMBER BEFORE
Beamline chamber after
VIISta 80 BEAMLINE CHAMBER AFTER
Hazardous waste accumulated
TOTAL AMOUNT OF HAZARDOUS WASTE ACCUMULATED

Scotch-Brite™ is a trademark of 3M Corporation