LAM 2300 Exelan Flex Oxide Etch Chamber
OBJECTIVE:
TO EFFECTIVELY PM THE LAM 2300 EXELAN FLEX OXIDE ETCH CHAMBER IN A TIMELY MANNER, WHILE IMPROVING TOOL RECOVERY AND PARTICLE PERFORMANCE
 
Vacuum Chamber: LAM 2300 EXELAN FLEX OXIDE ETCH
Vacuum Chamber Process Residue: PROCESS INDUCED RESIDUE
Vacuum Chamber Components:

CHAMBER, CHAMBER LINERS AND ASSOCIATED PARTS

Old Procedure:

2+ hours using silicon carbide scrubbing pads with ethanol (or equivalent final wipe solvent) 100+ wipes

Tool recovery: 6 to 8 hours conditioning wafers
New Procedure: 1 hour using 800D ScrubPAD, DI water & ethanol (or equivalent final wipe solvent)
Tool recovery: <4 Hours conditioning wafers
Foamtec Products
Vacuum Chamber Products:
LAM2300 EXELAN OXIDE ETCH PM KIT
PM Kit P/N: HT4500-LAM23-OX1
(1) HT4754 UltraSOLV® Sponge
(2) HT4580D-10-1 800 Grit Diamond ScrubPAD
(4) HT1511FC-5 MiraSWABS® (20pc)
(1) HT5790S-25 MiraWIPES® (25pc)
LAM 2300 Exelan Flex Oxide Etch PM Procedure:
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines, shutdown and prepare LAM 2300 Exelan Flex Chamber for wet clean
Step 2: Properly stage a container of DI water next to the chamber and place a Foamtec International HT4580D ScrubPAD and HT4754 UltraSOLV® Sponge into the container (See Fig 1)
ScrubPAD and Sponge
Fig 1: ScrubPAD and UltraSOLV® Sponge in container of DI water
NOTE: MAY SUBSTITUTE A SMALL AMOUNT OF DI WATER TO MOISTEN UltraSOLV® SPONGE AND ScrubPAD AS NECESSARY (See Fig 2 & 3)
ScrubPAD and Sponge with DI water
Dampening Sponge
Fig 2: UltraSOLV® Sponge, ScrubPAD and small amount of DI water
Fig 3: Dampening UltraSOLV® Sponge with DI water
Step 3: Use the lightly dampened UltraSOLV® Sponge and wipe Oxide ETCH Chamber liners (See Fig 4)
Wiping chamber liners
Fig 4: Dampened UltraSOLV® Sponge wiping chamber liners
Step 4: Use a lightly dampened 800 Grit Diamond ScrubPAD and scrub off deposition from Oxide ETCH Chamber liner. It is important to keep area a little moist with DI water (See Fig 5 & 6)
Scrubbing chamber liner
Scrubbing chamber liner
Fig 5 & 6: Lightly dampened 800 Grit Diamond ScrubPAD scrubbing chamber liner; keep slightly moist with DI water
Step 5: Before oxide deposition has a chance to dry back onto the chamber liner, use lightly dampened UltraSOLV® Sponge and wipe deposition from chamber liner (See Fig 7 & 8)
Lightly dampened Sponge preparing to wipe
Clean chamber liner
Fig 7: Lightly dampened UltraSOLV® Sponge preparing to wipe chamber liner
Fig 8: Clean chamber liner after UltraSOLV® Sponge
Step 6: As Diamond ScrubPAD appears to load up with deposition, pull ScrubPAD across damp UltraSOLV Sponge. This will help keep ScrubPAD effectively removing oxide deposition from chamber liner (See Fig 9, 10 & 11)
ScrubPAD loaded with deposition
Pull ScrubPAD across Sponge
Unloaded ScrubPAd
Fig 9: ScrubPAD loaded with deposition
Fig 10: Pull ScrubPAD across UltraSOLV® Sponge
Fig 11: Unloaded ScrubPAD
Step 7: Continue to rinse UltraSOLV® Sponge in container of DI water as necessary to keep UltraSOLV® Sponge slightly moist and free of deposition (See Fig 12 & 13)
Loaded Sponge
Clean Sponge after DI water rinse
Fig 12: UltraSOLV® Sponge loaded with deposition
Fig 13: UltraSOLV® Sponge free of deposition after rinse in DI water
Step 8: Continue to repeat this SCRUB – WIPE – RINSE procedure outlined in steps 4 through 7 for the remainder of the LAM 2300 Oxide ETCH parts (See Fig 14, 15 & 16)
Scrubbing
Wiping
Scrubbing
Fig 14, 15 & 16: Continuing SCRUB – WIPE – RINSE procedure on remaining Oxide ETCH Chamber parts
Step 9: Using same technique described above, take 800 Grit Diamond ScrubPAD and gently remove dark build-up on heater coils (See Fig 17)
ScrubPAD removing build-up

Fig 17: 800 Grit Diamond ScrubPAD removing build-up on heater coils
FINAL WIPE PROCEDURE:
IMPORTANT NOTE

IN ORDER TO HELP WITH AN EFFECTIVE TOOL RECOVERY, FOAMTEC INTERNATIONAL WIPE DOWN PROCEDURE MUST BE FOLLOWED WITH ALL HT5790S MiraWIPES® AND HT1511FC MiraSWABS®. THE MICRO-FIBER CHARACTERISTICS OF THESE PRODUCTS HELP REMOVE MORE DEPOSITION FROM THE PARTS THAN ANY OTHER STANDARD FAB WIPER

 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 18a & 18b)
MiraWIPES are more effective
Fig 18a: Current fab wiper after completely wiping the LAM 2300
Fig 18b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Step 10: After scrubbing heater coils use the HT1511FC MiraSWAB® dampened with alcohol and clear out all openings on heater plate (See Fig 19 & 20)
MiraSWABS cleaning additional openings
Additional deposition found by MiraSWAB
Fig 19: HT1511FC MiraSWAB® clearing out openings on heater plate
Fig 20: Additional deposition MiraSWAB® was able to remove from openings
Step 11: While using the HT1511FC MiraSWABS® to clear out all the openings within the heater coils, also use the HT5790S MiraWIPES® dampened with alcohol and proceed to wipe the entire heater plate, concentrating on the tight corners throughout the heater plate (See Fig 21 & 22)
Wiping with MiraWIPE and alcohol
Fig 21: Wiping heater plate with HT5790S MiraWIPE® and alcohol
Plate after scrub and wipe down
Fig 22: Clean heater plate coils after gentle scrub and wipe
Step 12: Following the same procedure with the HT1511FC MiraSWABS® and HT5790S MiraWIPES® with alcohol, perform an entire wipe of the remaining Oxide ETCH parts prior to placing back into the Oxide ETCH Chamber (See Fig 23)
Final wipe with MiraWIPE
Fig 23: HT5790S MiraWIPE® performing final wipe on all chamber parts
NOTE: THE FOLLOWING SHOWS HOW MUCH MORE DEPOSITION THE MiraWIPE® WAS ABLE TO REMOVE FROM A SMALL SECTION OF THE SILICONE RING AFTER A COMPLETE WIPED DOWN WITH THE STANDARD FAB WIPER (See Fig 24 & 25)
Deposition removed
Additional deposition
Fig 24 & 25: THE IMPORTANCE OF USING THE HT5790S MiraWIPES®
CHAMBER CLEAN:
Step 13: Take the additional 800 Grit Diamond ScrubPAD and using the same technique described above proceed to perform a chamber scrub on the LAM 2300 Exelan Flex Oxide Chamber
NOTE: Ensure to concentrate on the heavy deposition areas that are not covered by the chamber liners, such as the sides of the e-chuck (See Fig 26)

Scrubbing edge of e-chuck
Fig 26: 800 Grit Diamond ScrubPAD gently scrubbing edge of e-chuck
Step 14: When entire chamber scrub is complete, use the same technique described above and use remaining HT1511FC MiraSWABS® and HT5790S MiraWIPES® with alcohol and perform a complete chamber wipe down (See Fig 27 & 28)
Applying alcohol
Final wipe
Fig 27: Applying alcohol to HT5790S MiraWIPE®
Fig 28: Performing final wipe of LAM Oxide Chamber
TOOL RECOVERY:
Step 15: Follow proper tool recovery guidelines as outlined by LAM Research Corporation