OBJECTIVE:
TO EFFECTIVELY PM THE LAM OXIDE ETCH HOT PLATE IN A TIMELY MANNER, WHILE IMPROVING TOOL RECOVERY AND REDUCING PARTICLE PROBLEMS ASSOCIATED WITH TRYING TO CLEAN WITH SCOTCH-BRITE™
 
Vacuum Chamber: LAM 2300 EXELAN FLEX OXIDE ETCH
Vacuum Chamber Process Residue: ACCUMULATED RESIDUE FROM BACKSIDE OF ELECTRODE
Vacuum Chamber Components: HOT PLATE
Old Procedure:

1+ hours using Scotch-Brite™, IPA and fab wipers

Recovery time: Varies with particle issues
Interval: PM Hot Plate on every LAM OXIDE ETCH PM every two weeks
New Procedure: 1 hour using Diamond ScrubPAD, ScrubWRIGHT™ Pen, MiraWIPE® and MiraSWABS®
Recovery time: Improved recovery time with particle reduction
Foamtec Products
Vacuum Chamber Products:
LAM 2300 OXIDE ETCH HOT PLATE PM KIT
PM Kit P/N: HT4500-LAMHP1
(1) HT9423 CushionPAD 24” X 24”
(1) HT4536D-10-1 360 Grit Diamond ScrubPAD
(1) HT4536DW-1 360 Grit Diamond ScrubBELT®
(1) FTPEN-1 ScrubWRIGHT™ PEN
(1) HT4754 UltraSOLV® Sponge
(2) HT1511FC-5 MiraSWABS® (10 MiraSWABS®)
(2) HT5790S-5 MiraWIPES® (10 MiraWIPES®)
 
LAM 2300 Exelan Flex Hot Plate PM Procedure:
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines remove LAM OXIDE ETCH Hot Plate from ETCH Chamber and prepare for PM
Step 2: Place HT9423 Foam CushionPAD onto a flat solid work area, this will protect the hot plate during the cleaning procedure (See Fig 1)
Cushion Pad
Fig 1: Foam CushionPAD to be placed on flat work area
Step 3: Safely place hot plate on top of CushionPAD (See Fig 2)
Hot plate on cushion pad
Fig 2: Hot plate placed on top of Foam CushionPAD
Step 4: Take the HT4754 UltraSOLV® Sponge and lightly dampen with DI water (See Fig 3)
Dampen UltraSOLV Sponge
Fig 3: Lightly dampen UltraSOLV® Sponge with DI water
Step 5: Using the lightly dampened UltraSOLV® Sponge, pre-wipe the entire hot plate to remove any flaking or loose buildup (See Fig 4)
Wiping hot plate
Fig 4: UltraSOLV® Sponge pre-wiping the hot plate
Step 6: Lightly dampen the HT4536D 360 Grit Diamond ScrubPAD with DI water and proceed to gently scrub off the buildup on top of the hot plate (See Fig 5 & 6)
Dampen ScrubPAD
Scrub build-up
Fig 5: Lightly dampen ScrubPAD with DI water
Fig 6: Gently scrub off buildup throughout ETCH hot plate
Step 7: Using the lightly dampened UltraSOLV® Sponge wipe away the buildup as it becomes loose on top of the hot plate (See Fig 7)
Remove loose build-up
Fig 7: Lightly dampened UltraSOLV® Sponge removing loose buildup on top of hot plate
Step 8: As Diamond ScrubPAD begins to load up with deposition, pull ScrubPAD across UltraSOLV® Sponge to unload (See Fig 8, 9 & 10)
ScrubPAD loaded with deposition
Pull ScrubPAD across Sponge
Unloaded ScrubPAD
Fig 5: ScrubPAD loaded with deposition
Fig 6: Pull ScrubPAD across UltraSOLV® Sponge
Fig 7: Unloaded ScrubPAD
Step 9: Continue to rinse UltraSOLV® Sponge with DI water as sponge begins to load up with deposition (See Fig 11 & 12)
Dampen ScrubPAD
Scrub build-up
Fig 11: UltraSOLV® Sponge loaded with deposition
Fig 12: UltraSOLV® Sponge free of deposition after rinse in DI water
Step 10: Repeat steps 4 – 9, scrubbing the remaining areas of the LAM ETCH Hot Plate, ensuring to rinse UltraSOLV® Sponge and unload 360 Grit Diamond ScrubPAD, as necessary
Step 11: Use HT4536DW 360 Grit Diamond ScrubBELT® with FTPEN-1 ScrubWRIGHT™ Pen to clean around any hard to reach areas, such as the “guide pins” that normally get very dirty (See Fig 13)
FTPEN

Fig 13: Tip of FTPEN-1 scrubbing off buildup from hard to reach areas
NOTE: WHEN USING THE FTPEN-1, ENSURE TO ROTATE THE ScrubBELT® AROUND THE PEN AS NECESSARY TO KEEP A FRESH PORTION OF THE ScrubBELT® AVAILABLE AT THE TIP OF THE FTPEN. THIS IS THE AREA YOU ARE USING WHEN GENTLY SCRUBBING ANY DETAILED AREAS
FINAL WIPE PROCEDURE:
IMPORTANT NOTE
THE USE OF HT5790S MiraWIPES® AND HT1511FC MiraSWABS® DURING FINAL WIPE PORTION OF PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVING PARTICLE DEFECTS FROM THE HOT PLATE
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 10a & 10b)
MiraWIPES are more effective
Fig 10a: Current fab wiper after completely wiping the hot plate
Fig 10b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
 
Red Arrow
Red Arrow
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Step 12: Once scrubbing off buildup throughout hot plate is complete, saturate the HT5790S MiraWIPE® with IPA and perform an initial wipe down of hot plate (See Fig 15 & 16)
Saturate with IPA
Wipe with MiraWIPES
Fig 15: Saturate MiraWIPES® with IPA for initial wipe down
Fig 16: Perform an initial wipe down of hot plate using MiraWIPES®
Step 13: Replace MiraWIPE® with a fresh MiraWIPE® as necessary, and continue wiping hot plate until MiraWIPE® is no longer able to remove visible film
Step 14: When initial wipe down of hot plate is complete, place the HT1511FC MiraSWABS® into a MiraWIPE® and saturate with IPA (See Fig 17)
Saturating wit IPA
Fig 17: Placing MiraSWABS® into a MiraWIPE® and saturating with IPA
Step 15: Take saturated MiraSWABS® and wipe off build up from all the hard to reach areas throughout hot plate assembly (See Fig 18 & 19)
MiraSWAB
MiraSWAB
Fig 18 & 19: Saturated MiraSWABS® removing film from hard to reach areas throughout hot plate
NOTE: IMPORTANT TO USE MiraWIPES® ALONG WITH THE MiraSWABS® AS THE SWABS WILL REMOVE LOOSE DEPOSITION FROM THE HARD TO REACH AREAS THROUGHOUT THE ETCH HOT PLATE
MiraSWABs
MiraWIPES® and MiraSWABS® are the KEY STEPS for DEFECT REDUCTION and IMPROVED TOOL RECOVERY

Scotch-Brite™ is a trademark of 3M Corporation