Home > Documents > Application Notes > LAM 2300 Metal Heavy Deposition
Click Here for Printer Friendly Version
Before Foamtec Logo After
BEFORE AFTER
Vacuum Chamber PM Technique
LAM 2300 Metal ETCH Chamber: Heavy Deposition
OBJECTIVE:

TO EFFECTIVELY PM THE LAM 2300 METAL ETCH CHAMBER IN A TIMELY MANNER, WHILE IMPROVING TOOL RECOVERY AND PARTICLE PERFORMANCE

 
Vacuum Chamber: LAM 2300 METAL ETCH   
Vacuum Chamber Process Residue: PROCESS INDUCED RESIDUE
Vacuum Chamber Components: CHAMBER, SLIT VALVE, CHUCK AND PARTS
Old Procedure: 6 HOURS, THREE TECHS, using Scotch-Brite™, DI water, 150+ wipes & IPA  
New Procedure: 2 HOURS, ONE TECH, Foamtec HT4500-LAM23-1 PM Kit, DI water & IPA
Foamtec products
Vacuum Chamber Products:
LAM2300 METAL ETCH CHAMBER PM KIT
PM Kit P/N:  HT4500-LAM23-1
Heavy Deposition
  • (1) HT4754 UltraSOLV® Sponge
  • (4) HT4536D-10-1  360 Grit Diamond ScrubPAD
  • (1) HT5790S-25 MiraWIPES®                                                         
 
Novellus INOVA PVD Process Chamber PM Procedure:
View “How to” instructional videos on http://foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines, shutdown and prepare LAM 2300 Metal ETCH Chamber for wet clean
Step 2: Properly stage a container of DI water next to the chamber and place a   HT4536D 360 Grit Diamond ScrubPAD and HT4754 UltraSOLV® Sponge into the container (See Fig 1)
  Container of DI water with ScrubPAD and UltraSOLV® Sponge      
 

Fig 1: Container of DI water with ScrubPAD and UltraSOLV® Sponge

 
Step 3: Take damp UltraSOLV® Sponge and begin wiping Metal ETCH Chamber allowing the water to react with the process induced residue.  Remove as much of the deposition as possible with the sponge (See Fig 2)

This initial wipe portion of PM will take 20-25 minutes, and if performed properly, will be able to remove much of the deposition with just the sponge

 
\
 

 

  Dampened UltraSOLV® Sponge wiping Metal ETCH Chamber  
 

Fig 2:  Dampened UltraSOLV® Sponge wiping Metal ETCH Chamber

 
Step 4: It will be important to keep the UltraSOLV® Sponge moist and clear of excess deposition by replacing the sponge into the container of DI water and rinsing clear (See Fig 3)
 
NOTE: The Metal ETCH Chamber will be very hot; therefore, it will require rinsing the sponge frequently in the DI water in order to keep it moist
 
  Rinsing Sponge  

 

Fig 3:  Rinsing UltraSOLV® Sponge in container of DI water

 
 
 
Step 5: After performing initial wipe with the UltraSOLV® Sponge for at least 20 minutes, take the moist 360 Grit Diamond ScrubPAD from the container of DI water and begin scrubbing the Metal ETCH Chamber (See Fig 4)

Ensure to keep the ScrubPAD moist during scrub portion of PM by replacing it in the container of DI water as necessary

 
  Scrubbing chamber wall      
 

Fig 4: 360 Grit Diamond ScrubPAD scrubbing chamber wall

 
 
Step 6: Be prepared to wipe the scrubbed portion of the chamber with the dampened UltraSOLV® Sponge immediately after scrubbing with the 360 Grit Diamond ScrubPAD, ensuring not to let the wet deposition dry onto the chamber wall (See Fig 5)
 

      UltraSOLV Sponge wiping Metal ETCH Chamber during scrub portion of PM  
 

Fig 5:  UltraSOLV® Sponge wiping Metal ETCH Chamber during scrub portion of PM

 
 
Step 7: Pull ScrubPAD across the UltraSOLV® Sponge in one direction to free ScrubPAD of deposition (See Fig 6, 7 & 8)
ScrubPAD loaded with deposition
Pull ScrubPAD across sponge
Unloaded ScrubPAD
Fig 6: ScrubPAD loaded with deposition
Fig 7: Pull ScrubPAD across UltraSOLV® Sponge
Fig 8: Unloaded ScrubPAD
Step 8: Continue to return UltraSOLV® Sponge and 360 Grit Diamond ScrubPAD to the container of DI water to rinse free of deposition (See Fig 9 & 10)
Loaded UltraSOLV Sponge
UltraSOLV after rinse
Fig 9: Loaded-up UltraSOLV® Sponge
Fig 10: UltraSOLV® Sponge AFTER rinse
NOTE: Continue to repeat this SCRUB – WIPE – RINSE procedure outlined in steps 5 - 8 for the remainder of the Metal ETCH Chamber.  The KEY POINT is to not let the wet deposition dry onto the chamber wall               
 
Step 9: Replace container with fresh DI water after completing half of Metal ETCH Chamber scrub
 
Step 10: Replace HT4536D 360 Grit Diamond ScrubPAD with a new one when ScrubPAD appears worn (expect to use three on chamber, one for e-chuck and door assembly
 
Step 11: Using same procedure as described above, proceed to SCRUB – WIPE – RINSE the bottom portion of the e-chuck assembly and chamber door mount (See Fig 11 & 12)
 
Removing deposition from bottom of e-chuck   Sponge removing scrubbed depostion from e-chuck
  Fig 11: Diamond ScrubPAD removing deposition from bottom of e-chuck   Fig 12: UltraSOLV® Sponge removing scrubbed deposition from e-chuck  
 
NOTE: May remove deposition buildup on e-chuck ceramic ring if desired (See Fig 13)
 

      Clean ceramic ring  
 

Fig 13: Clean ceramic ring

 
 
Step 12: Rinse out UltraSOLV® Sponge in fresh DI water.  Prepare Metal ETCH Chamber for FINAL WIPE PROCEDURE by wiping all areas of chamber completely with dampened UltraSOLV® Sponge
 

FINAL WIPE  PROCEDURE:

 
IMPORTANT NOTE:
 
MUST USE HT5790S MiraWIPES® DURING WIPE PORTION OF PROCEDURE TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM LAM 2300 METAL ETCH CHAMBER
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 14a & 14b)
MiraWIPES are more effective
Fig 14a: Current fab wiper after completely wiping chamber
Fig 14b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
 
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Step 13: Ensure to remove gloves and replace with a fresh set prior to FINAL WIPE PROCEDURE
 
Step 14: Using 100% IPA, dampen the HT5790S MiraWIPES® and perform a THOROUGH AND EFFECTIVE FINAL WIPE PROCEDURE of the entire LAM 2300 Metal ETCH Chamber, e-chuck, slit valve, pump ports, view ports, and all associated parts being replaced under the hi-vac within the chamber
 
TOOL RECOVERY:
 
Step 15: Follow proper Tool Recovery guidelines as outlined by LAM Research Corporation

Scotch-Brite™ is a trademark of 3M Corporation