Home > Documents > Application Notes > LAM 9600 Super Clean 2
Click Here for Printer Friendly Version
Before
Foamtec Logo
After
BEFORE AFTER
Vacuum Chamber PM Technique
LAM 9600 Metal ETCH Super Clean #2

OBJECTIVE:

TO EFFECTIVELY PM THE LAM 9600 METAL ETCH IN A TIMELY MANNER, WHILE MINIMIZING PARTICLE ISSUES, REDUCING HAZARDOUS WASTE AND IMPROVING TOOL PERFORMANCE
 
Vacuum Chamber: LAM 9600 METAL ETCH
Vacuum Chamber Process Residue: PROCESS INDUCED RESIDUE
Vacuum Chamber Components: CHAMBER, PUMP PORT, TURBO TUNNEL, SLIT VALVE
Old Procedure: Scotch-Brite™, DI water, wipers and IPA
 
New Procedure: Foamtec products, DI water, MiraWIPES® and IPA
Vacuum Chamber Products:
  • (2) HT4528A-10 280 Grit UltraSOLV® ScrubPAD
  • (1) HT4754 UltraSOLV® Sponge
  • (1) HT5790S-25 MiraWIPES®
NOTE: INITIAL CLEAN MAY REQUIRE THE USE OF ADDITIONAL PRODUCTS TO EFFECTIVELY CLEAN CHAMBER BACK TO BARE METAL
RECOMMEND: PERFORM A ROUND OF 2-3 PM'S ON SAME TOOL TO ESTABLISH SUFFICIENT DATA FOR EVALUATION
LAM 9600 Metal Etch Super Clean #2 PM Procedure:
View “How to” instructional videos at http://www.foamtecintlwcc.com/video/
Step 1: Using proper procedures and safety guidelines properly shutdown and vent entire Metal ETCH chamber
Step 2: Reduce ETCH chamber heater settings to 35oC to 40oC
Step 3: Place HT4754 UltraSOLV® Sponge, UltraSOLV® 280 Grit Diamond ScrubPAD in container with approximately 1 liter of DI water (See Fig 1)
 
      Diamond ScrubPAD, Sponge & 1 liter DI Water  
 

Fig 1: 280 Grit Diamond ScrubPAD, Sponge & 1 liter DI water Note Time: 9:35

 
 
Step 4: Using the dampened UltraSOLV® Sponge, proceed to wipe down all areas throughout Metal ETCH chamber, slit valve and turbo tunnels as this will remove any flakes and gross deposition buildup (See Fig 2 & 3) 
 
NOTE: CONTINUE TO RE-SOAK AND DAMPEN THE ULTRASOLV® SPONGE AS NECESSARY
         
  Dampened UltraSOLV Sponge initial wipe of chamber   Etch Chamber after initial wipe with UltraSOLV Sponge  
  Fig 2: Dampened UltraSOLV® Sponge initial wipe of chamber   Fig 3: ETCH Chamber following initial wipe with UltraSOLV® Sponge  
 
Step 5: With UltraSOLV® Sponge, dampen and moisten a 6” to 8” scrubbing area within the chamber
 
Step 6: With dampened UltraSOLV® 280 Grit Diamond ScrubPAD, proceed to scrub off deposition from moistened area
 
Step 7: To help unload ScrubPAD and UltraSOLV® Sponge of deposition, continually return them back into container of DI water as necessary.  It will also be effective to unload the ScrubPAD of deposition by pulling across the UltraSOLV® Sponge in one direction (See Fig 4, 5 & 6)
ScrubPAD loaded with deposition
Pull ScrubPAD across Sponge
Unloaded ScrubPAD
Fig 4: ScrubPAD loaded with deposition
Fig 5: Pull ScrubPAD across UltraSOLV® Sponge
Fig 6: Unloaded ScrubPAD
 
Step 8: Continue to repeat process throughout entire chamber until all deposition is removed.  It is important to keep the ScrubPAD and chamber moist with DI water during clean
Step 9: As water becomes filled with deposition, recommend disposing dirty DI water in appropriate hazardous waste collection tank and replacing with fresh DI water
Step 10: After all areas within entire chamber have been effectively cleaned, take freshly rinsed out UltraSOLV® Sponge and thoroughly wipe out and prep the chamber for FINAL IPA WIPE PROCEDURE (See Fig 7)  
 
      Chamber Scrub Complete  
 

Fig 7: Chamber Scrub CompleteDiamond ScrubPAD & UltraSOLV® Sponge ONLY products used for scrub portion of PM.  Note time:  10:06 Less than 1 hour to complete scrub

 
 
FINAL WIPE PROCEDURE:
IMPORTANT NOTE
THE USE OF HT5790S MiraWIPES® DURING THE FINAL WIPE PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM THE LAM 9600. CONTINUE TO WIPE-DOWN ALL OF THE AFFECTED PM AREAS WITHIN THE ETCH CHAMBER REPEATEDLY UNTIL ALL MIRAWIPES® NO LONGER REMOVE ANY MORE DEPOSITION
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 8a & 8b)
MiraWIPES are more effective
Fig 8a:Current fab wiper after completely wiping the LAM 9600
Fig 8b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
 
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Step 11: Using 100% IPA, dampen the HT5790S MiraWIPES® and perform a THOROUGH AND EFFECTIVE FINAL WIPE-DOWN of the ETCH Chamber, chamber door, slit valve, turbo tunnel, o-ring grooves and all sealing surfaces
Step 12: Ensure to wipe down all spare parts placed back into the LAM 9600 Metal ETCH chamber using additional IPA dampened HT5790S MiraWIPES®

Scotch-Brite™ is a trademark of 3M Corporation