Home > Documents > Application Notes > Plt Versalock 700
Click Here for Printer Friendly Version
Before Foamtec Logo After
BEFORE AFTER
Vacuum Chamber PM Technique
Plasmatherm Versalock 700 Chamber
OBJECTIVE:

TO PM THE PLASMATHERM VERSALOCK 700 CHAMBER IN AN EFFECTIVE AND TIMELY MANNER WHILE IMPROVING PARTICLE PERFORMANCE, TOOL RECOVERY AND MAXIMIZING TOOL UPTIME

 
Vacuum Chamber: PLT VERSALOCK 700 CHAMBER
Vacuum Chamber Process Residue: VARIOUS HARD OXIDE, NITRIDE, AND GLASSLIKE RESIDUES
Vacuum Chamber Components:

CERAMIC DOME, CERAMIC CLAMP PLATE, WAFER PEDESTAL, CHAMBER WALLS

Old Procedure: Scotch-Brite™, commercial grade sandpaper and clean room wipers. Hard, lengthy scrubbing regimes generate large amounts of particles
Solvent: DI Water and IPA
Safety:

BA to prevent breathing in dangerous fumes

Vacuum Chamber Products:
  • (2) HT4754 UltraSOLV® Sponge
  • (4) HT4536DC3-1 360 Grit Diamond ScrubDISK®
  • (2) HT4536D-10-1 360 Grit Diamond ScrubPAD (optional)
  • (1) HT4580D-10-1  800 Grit Diamond ScrubPAD
  • (1) FS206 ScrubCLEAN™ Light Duty Abrasive Sponge
  • (1) FT901 ErgoSCRUB®Soft Handle w/Loop
  • (1) HT5790S-25 MiraWIPES®
  • (1) Container that can hold 1 liter of DI water
Plasmatherm Versalock 700 Chamber PM Procedure:
View “How to” instructional videos on http://www.foamtecintlwcc.com/video/
Pre-Cleaning the Tool:
Step 1: Wipe-down inside of the chamber, ceramic dome and ceramic clamp ring using a DI water dampened UltraSOLV® HT4754 Sponge 
 
Scrubbing the Tool:
CERAMIC DOME 
 
Step 2: Using DI water dampened HT4536DC3-1 ScrubDISK®, attached to the FT901 ErgoSCRUB®, scrub an 8”x8” area within the ceramic dome
 
Step 3: Wipe-down the affected area using the DI water dampened HT4754 UltraSOLV® Sponge
Step 4: Unload the ScrubDISK® of deposition by wiping the HT4754 UltraSOLV® Sponge with the ScrubDISK® in one direction (See Fig 1, 2 & 3)
Loaded ScrubDISK
Pull ScrubDISK across Sponge
Unloaded ScrubDISK
Fig 1: ScrubDISK® loaded with deposition
Fig 2: Pull and Twist ScrubDISK® across UltraSOLV® Sponge
Fig 3: Unloaded ScrubDISK®
Step 5: Unload the HT4754 UltraSOLV® Sponge by moistening with DI water and ringing out into a HazMat container (See Fig 4 & 5)
Loaded UltraSOLV Sponge
UltraSOLV after rinse
Fig 4: Loaded-up UltraSOLV® Sponge
Fig 5: UltraSOLV® Sponge AFTER rinse
Step 6: Repeat steps 2 – 5, using the HT4536DC3-1 ScrubDISK® attached to the FT901 ErgoSCRUB® where necessary until all deposition is removed from ceramic dome
 
Step 7: Using the HT4536DC3-1 ScrubDISK® attached to the FT901 ErgoSCRUB®, remove the rainbow stain from the metal section above ceramic dome.  Use the same procedure as employed for cleaning the ceramic dome.  If necessary remove the ScrubDISK® from the ErgoSCRUB® Handle to get at hard to reach areas or use a HT4536D-10-1 UltraSOLV® ScrubPAD
 
Step 8: Repeat step 7 until rainbow stain has been removed from the metal section
 
Step 9: Using the HT4580D-10-1 UltraSOLV® ScrubPAD, polish the metal section above ceramic dome.  Repeat actions used in step 4 and 5 to unload deposition from ScrubPAD
 
NOTE: ENSURE CERAMIC CLAMP RING IS IN THE DOWN POSITION
 
Step 10: Using DI water dampened HT4536DC3-1 UltraSOLV® ScrubDISK®, attached to the FT901 ErgoSCRUB® and scrub a small area at a time, taking great care not to scrub the wafer pedestal
 
Step 11: Wipe-down the affected area using the DI water dampened UltraSOLV® HT4754 Sponge
 
Step 12: Unload the ScrubDISK® of deposition by wiping the UltraSOLV® HT4754 Sponge with the ScrubDISK® in one direction (See Fig 1, 2 & 3)
 
Step 13: Unload the UltraSOLV® HT4754 Sponge by moistening with DI water and ringing out into a HazMat container (See Fig 4 & 5)
 
Step 14: Repeat steps 9 – 13, using the HT4536DC3-1 ScrubDISK® attached to the FT901 ErgoSCRUB® where necessary, until all deposition is removed from ceramic clamp ring
Before
After
Fig 6: Ceramic clamp ring before clean
Fig 7: Ceramic clamp ring after clean
Step 15: Using DI water dampened FS206 ScrubCLEAN™, lightly scrub a small area of the wafer pedestal at a time
Step 16: Wipe-down the affected area using the DI water dampened UltraSOLV® HT4754 Sponge
 
Step 17:

Repeat steps 15 – 16, until satisfied that wafer pedestal has been cleaned

 
CHAMBER WALLS
 
Step 18: Using DI water dampened HT4580D-1 ScrubPAD, scrub an 8”x8” area within the chamber walls.  Include area around ceramic dome
 
Step 19: Wipe-down the affected area using the DI water dampened UltraSOLV® HT4754 Sponge
 
Step 20: Unload the ScrubDISK® of deposition by wiping the UltraSOLV® HT4754 Sponge with the ScrubDISK® in one direction (See Fig 1, 2 &3)
 
Step 21: Unload the UltraSOLV® HT4754 Sponge by moistening with DI water and ringing out into a HazMat container (See Fig 4 & 5)
 
Step 22: Repeat steps 19 – 21, using the HT4580D-10-1 ScrubPAD where necessary, until all deposition is removed from chamber walls
Chamber walls
Metal ring
Fig 8: Chamber walls
Fig 9: Metal ring around ceramic dome
FINAL WIPE PROCEDURE:
IMPORTANT NOTE
THE USE OF HT5790S MiraWIPES® DURING THE FINAL WIPE PORTION OF THE PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM THE PLT VERSALOCK 700 CHAMBER
 
Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 10a & 10b)
MiraWIPES are more effective
Fig 10a: Current fab wiper after completely wiping the Versalock 700
Fig 10b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper
Red Arrow
Red Arrow
 
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY
Ensure to wipe wafer pedestal area under clamp ring
Step 23: Work from the top down starting with the metal section above the ceramic dome, repeatedly wiping around using an IPA dampened HT5790S MiraWIPE®.  Ensure to wipe effectively until all areas are removed of deposition 
Step 24: Ensure to raise the ceramic clamp ring so as to remove any debris under the clamp ring and wafer pedestal.  Ensure to wipe effectively until all areas are removed of deposition 
 
Clamp ring in the up position for final wipe                  
 
 
 
 
Ensure to wipe wafer pedestal area under clamp ring
 
 
 
 
 
 
Fig 11: Clamp ring in the up position for final wipe

Scotch-Brite™ is a trademark of 3M Corporation