| Thick-Film/Paste/Ink Mixing Equipment Clean PM Procedure: |
| |
| View “How to” instructional videos on http://foamtecintlwcc.com/video/ |
|
| Step 1: |
Proceed to fill BCO1750 BenchCan with 1.5 liters of solvent |
| |
| Step 2: |
Remove parts (i.e. nozzles, valves, gaskets, etc.) from mixing equipment that is required to be cleaned |
| |
| Step 3: |
Gently submerge (1) HT4699 UltraSORB® Wiper into the BenchCan ringing out any excess solvent from UltraSORB® Wiper |
| |
| Step 4: |
Fold the UltraSORB® Wiper into quarters and proceed to wipe residual product left behind on mixing equipment. Refold UltraSORB® Wiper as it becomes loaded with deposition to expose a cleaner portion of the UltraSORB® Wiper – continue wiping |
| |
| Step 5: |
As the UltraSORB® Wiper becomes loaded with deposition, re-submerge wiper into BenchCan continually ring out any excess deposition and solvent from the UltraSORB® Wiper. Re-fold UltraSORB® Wiper into quarters and continue wiping mixing equipment |
| |
| NOTE: |
BenchCan solvent should be replaced when rung-out wiper leaves smears of paste/ink on surface being cleaned |
| |
| Step 6: |
When the UltraSORB® Wiper appears to have lost the majority of its strength, squeeze as much of the solvent/paste back into the BenchCan then dispose of wiper into properly labeled hazardous waste container |
| |
| Step 7: |
Repeat steps 3 – 6 with the 2nd HT4699 UltraSORB® Wiper |
| |
| Step 8: |
FINAL WIPE-DOWN: Fold the remaining clean HT4699 UltraSORB® Wiper into quarters and apply a small amount of fresh solvent. Perform a final wipe-down, refolding the UltraSORB® Wiper as necessary to complete an effective clean on the mixing equipment |
| |
| NOTE: |
UltraSORB® Wipers remain in excellent condition, operator still able to effectively clean remaining mixing equipment |