| Click Here for Printer Friendly Version | ||
![]() |
![]() |
![]() |
| BEFORE | AFTER | |
| Vacuum Chamber PM Technique | ||
| Varian VIISta HC Process Chamber | ||
| OBJECTIVE: | ||
TO EFFECTIVELY PM THE VARIAN HC PROCESS CHAMBER IN A TIMELY MANNER TO HELP MINIMIZE PARTICLE ISSUES AND IMPROVE TOOL PERFORMANCE |
||
| Vacuum Chamber: | VARIAN VIISTA HC | |
| Vacuum Chamber Process Residue: | PROCESS INDUCED RESIDUE | |
| Vacuum Chamber Components: | PROCESS CHAMBER |
| Old Procedure: | 2+ Hours using DI water & IPA with 150+ wipes | |
| Recovery time:12 hours | ||
| Interval: PM process chamber every 12 weeks | ||
| New Procedure: | 1.5 hour using Diamond ScrubPAD, ScrubWRIGHT™ Pen, MiraWIPE® and MiraSWABS® |
|
| Recovery time: 8 hours | ||
| PARTICLE PERFORMANCE: CHAMBER RECOVERED WITH <3 ADDERS at .16M | ||
![]() |
||
| Vacuum Chamber Products: | ||
VARIAN VIISta Process Chamber PM Kit |
||
| PM Kit P/N: HT4500-VARPC1 | ||
|
||
| Varian VIISta HC Process Chamber PM Procedure: | |
| View “How to” instructional videos on http://www.foamtecintlwcc.com/video/ | |
| Process Chamber Door Assembly Procedure (20 Minutes): | |
![]() |
![]() |
VARIAN VIISTA HC |
VARIAN VIISTA HC |
| Step 1: | Using proper procedures and safety guidelines prepare Varian VIISta HC Process Chamber for wet clean | |||
| Step 2: | Take the HT9423 CushionPAD and place onto a stable working area such as a workbench or clean area on the floor (See Fig 1) | |||
![]() |
||||
Fig 1: HT9423 CushionPAD onto stable working area |
||||
| Step 3: | Place the chamber door onto the CushionPAD and remove the o-ring in preparation for wet clean | |||
| Step 4: | Stage the appropriate parts for wet clean (See Fig 2) | |||
|
![]() |
|||
| Step 5: | Lightly moisten the HT4754 UltraSOLV® Sponge in the container of DI water and perform an initial wipe of the entire chamber door, in order to remove any loose process buildup and flakes (See Fig 3 & 4) |
![]() |
![]() |
|||
Fig 3: Lightly moisten UltraSOLV® with DI water |
Fig 4: Wipe chamber door with UltraSOLV® Sponge to remove any flakes |
|||
| Step 6: | Attach the HT4528DC3 280 Grit Diamond ScrubDISK® to the FT901 ErgoSCRUB® and moisten with DI water (See Fig 5 & 6) | |||||
![]() |
![]() |
|||
Fig 5: 280 Grit Diamond ScrubDISK® attached to ErgoSCRUB® handle |
Fig 6: Moisten ScrubDISK® with DI water |
|||
| Step 7: | Using the 280 Grit Diamond ScrubDISK® attached to the ErgoSCRUB®, scrub the deposition off a small 6” X 6” area on the chamber door (See Fig 7) | |||
![]() |
||||
Fig 7: Use ErgoSCRUB® with ScrubDISK® and scrub a small area on chamber door |
||||
| Step 8: | Use the lightly dampened UltraSOLV® Sponge to remove the excess deposition from the chamber door (See Fig 8 & 9) | |||
![]() |
![]() |
|||
Fig 8 & 9: Lightly dampened UltraSOLV® Sponge wiping away excess deposition |
||||
| Step 9: | Unload the deposition from the Diamond ScrubDISK® by pulling and twisting across the UltraSOLV® Sponge (See Fig 10, 11 & 12) | |||
![]() |
![]() |
![]() |
||||||
Fig 10: ScrubDISK® loaded with deposition |
Fig 11: Pull & twist ScrubDISK® across UltraSOLV® Sponge |
Fig 12: Unloaded ScrubDISK® |
||||||
| Step 10: | Using the same technique described above, continue to lightly moisten the ScrubDISK® and scrub off the deposition, then use the UltraSOLV® Sponge to remove the excess deposition from the remaining area on the chamber door (See Fig 13 & 14) | |||
![]() |
![]() |
|||
Fig 13: Scrubbing deposition from remaining areas on chamber door |
Fig 14: Wiping away excess deposition with UltraSOLV® Sponge |
|||
| Step 11: | After using the Diamond ScrubDISK® take the HT4528D 280 Grit Diamond ScrubPAD and using the same technique described above, remove any remaining deposition left on chamber door (See Fig 15) |
![]() |
||
Fig 15: Diamond ScrubPAD removing remaining deposition on chamber door |
||
| Step 12: | Continue to use the UltraSOLV® Sponge to remove excess deposition from chamber door; remember to rinse out UltraSOLV® Sponge and keep lightly dampened with DI water (See Fig 16 & 17) | ||
![]() |
![]() |
|||
Fig 16: Loaded-up UltraSOLV® Sponge |
Fig 17: UltraSOLV® Sponge AFTER rinse |
|||
| Step 13: | Turn the chamber door onto its side and using the HT4528D 280 Grit Diamond ScrubPAD and UltraSOLV® Sponge remove the deposition from the lip of the viewing window (See Fig 18 & 19) | ||||
![]() |
![]() |
|||
Fig 18: Diamond ScrubPAD scrubbing deposition from lip of chamber door |
Fig 19: UltraSOLV® Sponge removing excess deposition from lip of chamber door |
|||
| Step 14: | Place the HT4536DW 360 Grit Diamond ScrubBELT® onto the FTPEN-1 ScrubWRIGHT™ Pen and use it to reach the tight corners around the viewing window (See Fig 20 & 21) | |||
![]() |
![]() |
|||
Fig 20 & 21: ScrubWRIGHT™ Pen used for more detailed work around viewing window |
||||
| Step 15: | When deposition has been completely removed from chamber door, take the HT4580D 800 Grit Diamond ScrubPAD and using the same technique described above, gently polish over all the areas where the 280 Grit ScrubPAD was used – this will help keep the chamber in a polished state (See Fig 22) | ||||||
![]() |
|||||||
Fig 22: 800 Grit Diamond ScrubPAD used to polish chamber door after initial scrub |
|||||||
| Step 16: | Take the HT4513PD 1350 Grit Diamond ScrubPAD and, with plenty of DI water, GENTLY scrub off the deposition from the chamber viewing window (See Fig 23) | ||||||||||
![]() |
|||||||||||
Fig 23: 1350 Grit Diamond ScrubPAD gently removing deposition from window |
|||||||||||
| NOTE: | IT IS IMPORTANT TO USE PLENTY OF DI WATER WHEN USING THE 1350 Grit ScrubPAD ON THE VIEWING WINDOW TO PREVENT SCRATCHING WINDOW | ||||||||||
| Step 17: | Continue to use UltraSOLV® Sponge as before to remove the excess deposition from viewing window (See Fig 24) | ||||||||||
![]() |
|||
Fig 24: UltraSOLV® Sponge removing excess deposition from viewing window |
|||
| Step 18: | Rinse out the UltraSOLV® Sponge with DI water and wipe the entire chamber door assembly in preparation for the Final Wipe Procedure | ||
| FINAL WIPE PROCEDURE OF CHAMBER DOOR: | ||
IMPORTANT NOTE |
||
| THE USE OF HT5790S MiraWIPES® AND HT1511FC MiraSWABS® DURING THE FINAL WIPE PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM CHAMBER DOOR | ||
| Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 25a & 25b) | ||
![]() |
||
Fig 25a: Current fab wiper after completely wiping chamber door |
Fig 25b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper |
|
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY |
||
| Step 19: | Saturate the HT5790S MiraWIPE® with IPA and perform an initial wipe of the chamber door (See Fig 26 & 27) |
![]() |
![]() |
|||
Fig 26: Saturating HT5790S MiraWIPES® with IPA |
Fig 27: Performing an initial wipe of chamber door |
|||
| Step 20: | Take the HT1511FC MiraSWAB® and place on a HT5790S MiraWIPE®, and then saturate the MiraSWAB® with IPA (See Fig 28) | |
![]() |
||
Fig 28: Saturating HT1511FC MiraSWABS® with IPA |
||
| Step 21: | Take the saturated MiraSWAB® and wipe deposition out of all the tight corners and hard to reach areas, such as o-ring grooves (See Fig 29, 30 & 31) | |
![]() |
![]() |
|||
Fig 29 & 30: MiraSWABS® cleaning out tight areas and grooves along Process Chamber Door |
||||
![]() |
||||||
Fig 31: EXTRA DEPOSITION THE MiraSWABS® ARE ABLE TO REMOVE FROM AREAS ON CHAMBER DOOR |
||||||
MiraWIPES® and MiraSWABS® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY |
||
| Step 22: | Continue to saturate the HT5790S MiraWIPE® with IPA and perform a final wipe of the chamber door until no further deposition is removed from door assembly (See Fig 32) | |||
![]() |
||||
Fig 32: Completed Process Chamber Door PM |
||||
| VIISta HC Process Chamber PM (1 Hour): | ||||
| Step 23: | Using proper procedures and safety guidelines prepare Varian VIISta HC Process Chamber for wet clean | |||
| Step 24: | In preparation for Process Chamber wet clean, carefully cover the electrostatic clamp with a large plastic bag and place a light within the chamber (See Fig 33 & 34) | |||
![]() |
![]() |
|||
Fig 33 & 34: Electrostatic clamp carefully covered with large plastic bag |
||||
| Step 25: | Stage the appropriate parts needed for Process Chamber PM, most of the parts will be the same parts used for the Chamber Door PM | |
|
||
| NOTE: | THE PROCESS CHAMBER PM WILL FOLLOW THE SAME TECHNIQUE DESCRIBED ABOVE FOR THE PROCESS CHAMBER DOOR PM | |
| Step 26: | Lightly moisten the UltraSOLV® Sponge in the container of DI water and perform an initial wipe of the area that will be cleaned inside the Process Chamber, in order to remove any loose process buildup and flakes | |
| Step 27: | Attach the HT4528DC3 280 Grit Diamond ScrubDISK® to the FT901 ErgoSCRUB® and moisten with DI water (See Fig 35) | |
![]() |
||
Fig 35: 280 Grit Diamond ScrubDISK® attached to ErgoSCRUB® |
||
| Step 28: | Using the 280 Grit Diamond ScrubDISK® attached to the ErgoSCRUB®, scrub the deposition off a small 6” X 6” area within the process chamber (See Fig 36) | |
![]() |
|||
Fig 36: 280 Grit Diamond ScrubDISK® scrubbing deposition from Process Chamber |
|||
| Step 29: | Use the lightly dampened UltraSOLV® Sponge and proceed to remove the excess deposition from the scrubbed area within the process chamber | ||||
| Step 30: | Unload the deposition from the Diamond ScrubDISK® by pulling and twisting across the UltraSOLV® Sponge (See step 9 of Chamber Door Procedure | ||||
| Step 31: | Using the same technique described above, continue to lightly moisten the ScrubDISK®, scrub off the deposition, and use the UltraSOLV® Sponge to wipe the excess deposition from the remaining areas in the process chamber |
||||
| Step 32: | After using the Diamond ScrubDISK® take the HT4528D 280 Grit Diamond ScrubPAD and using the same technique described above, remove any remaining deposition left in the area to be scrubbed in the process chamber (See Fig 37) | ||||
![]() |
|||||
Fig 37: ScrubPAD cleaning all remaining areas within process chamber |
|||||
| Step 33: | When deposition has been completely removed from the area to be cleaned in the chamber, take the HT4580D 800 Grit Diamond ScrubPAD and, using the same technique described above, gently polish over all the areas where the 280 Grit Diamond ScrubPAD was used – this will help keep the process chamber in a polished state (See Fig 38) | ||||
![]() |
||||
Fig 38: 800 Grit Diamond ScrubPAD polishing process chamber |
||||
| FINAL WIPE PROCEDURE OF PROCESS CHAMBER: | ||||
| IMPORTANT NOTE | ||
| THE USE OF HT5790S MiraWIPES® AND HT1511FC MiraSWABS® DURING THE FINAL WIPE PROCEDURE IS A CRITICAL STEP TO EFFECTIVELY REMOVE PARTICLE DEFECTS FROM PROCESS CHAMBER | ||
| Figure below shows how much more deposition the Foamtec International MiraWIPE® can remove from a critical surface compared to the standard fab wiper, making the MiraWIPE® FINAL WIPE PROCEDURE the most CRITICAL STEP of the PM procedure (See Fig 39a & 39b) | ||
![]() |
||
Fig 39a: Current fab wiper after completely wiping chamber |
Fig 39b: Particles picked up using HT5790S MiraWIPES® after completely wiping with current fab wiper |
|
MiraWIPES® are the KEY STEP for DEFECT REDUCTION and IMPROVED TOOL RECOVERY |
||
| Step 34: | Carefully remove the plastic bag over the electrostatic clamp | |||
| Step 35: | Saturate the HT5790S MiraWIPE® with IPA and perform a final wipe of the process chamber (See Fig 40) | |||
![]() |
||||
Fig 40: Using the HT5790S MiraWIPES® to complete a final wipe of the process chamber |
||||
| Step 36: | Take the HT1511FC MiraSWAB® and place into a MiraWIPE®, and then proceed to saturate the MiraSWAB® with IPA (See Fig 41) | |||
![]() |
||||
Fig 41: Using the HT1511FC MiraSWABS® to wipe out the tight corners and hard to reach areas |
||||
| Step 37: | Continue to saturate the remaining MiraWIPES® with IPA and wipe out the process chamber until no further visible deposition is being removed by the MiraWIPE® | |||
| Step 38: | In order to help minimize back side particle problems it is important to use the HT4790 UltraSOLV® Foam Wiper to wipe the face of the electrostatic clamp – this will be the last step just prior to closing up the Process Chamber | |||
| Step 39: | Take a dry HT4790 UltraSOLV® Foam Wiper and fold into quarters, then wipe the face of the electrostatic clamp by pulling the foam wiper from the back to the front of the face (See Fig 42) | |||
![]() |
||||
Fig 42: Using the HT4790 UltraSOLV® Foam Wiper to wipe the face of the ESC from BACK to FRONT |
||||
| Step 40: | Refold the UltraSOLV® Foam Wiper exposing a clean side of the wiper and continue to wipe the remaining areas of the electrostatic clamp |
| Step 41: | Using the approved safety procedures and guidelines close the process chamber and return the tool back to production |