| Click Here for Printer Friendly Version |
cleaning critical surfaces
![]() CleanWIPE®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description |
CleanWIPE® is constructed from an open-cell, ester-based polyurethane medical grade foam and is completely free of fibers. CleanWIPE's® super fine pore structure and proprietory surface chemistry enable high volumes of disinfectant/cleaners to be evenly applied to clean room surfaces. CleanWIPE® is laundered with a proprietary process yielding a Class 100 wiper that is ideal for Medical Device and Pharmaceutical applications. Versions are available that are certified as non-cytotoxic. CleanWIPE® is compatible with EtO, Gamma and autoclave sterilization processes.
| Application Advantages |
| Fiber-Free. Open-cell polyurethane structure allows for fiber-free wiping. | |
| Improve Disinfection. CleanWIPES® uniform, super fine pore structure evenly apply alcohol, aldehyde, bleach, phenolic and quat-based disinfectants. | |
| Non-cytotoxic. Available certified non-cytotoxic and lot traceable to comply with FDA standard for the Medical Device industry. | |
| Chemically compatible. Will not interfere with curing of elastomers, platinum-cured silicones, adhesives and will not deactivate disinfectants. | |
| Cleaning ease. Sponge-like characteristic allow precise application of cleaning solutions to hard to clean areas such as isolators, conveyors and filling machines. | |
| Cost effective and environmentally safe. Efficient release of sterile alcohol and disinfectants enable reduced usage without reducing sanitization of aseptic surfaces. | |
| Available in small sizes. Reduced cost in applications such as catheter wipedown. |
| Cleanliness |
| Particle Generation (0.5 �) | ||||||
Wet Test (millions/m2) |
Dry Flex (particles/ft3) |
|||||
≤11 |
≤120 |
|||||
| Absorbency (ml/m2) | ||||||
Isopropyl Alcohol |
≥1020 |
|||||
| Time to 1/2 Absorption (seconds) | ≤3 |
|||||
| Extractables (g/m2) | ||||||
Deionized Water |
Isopropyl Alcohol |
1,1,1-TCE |
Freon |
|||
≤0.9 |
≤2.0 |
≤2.5 |
≤1.8 |
|||
| Ion Count of Extractables (PPM) | ||||||
Na+ |
K+ |
Cl- |
||||
≤15 |
≤2 |
≤5 |
||||
| Cytotoxicity - MEM Elution Method | PASS: Non-Cytotoxic | |||||
| Abrasive Study |
![]() |
![]() |
![]() |
![]() |
| UltraSORB® Wiper Out-of-the-Bag |
Standard Non-woven Wiper | UltraSORB® Wiper After Use on SMT |
Standard Non-woven Wiper |
| Methods of Use |
![]() |
![]() |
![]() |
||
Step 1: Quarter-fold Wiper after wetting with DI Water. For use with IPA, quarter-fold prior to wetting. |
Step 2: With all four fingers on top and the thumb on the underside of the Wiper, pull it across the surface of the tool using very light pressure. |
| Part Numbers |
| Part No. | Measurements | Bag Qty. | Case Qty. |
| HT4201 | .078” x 6” x 9” | 25/bag | 130 bags/case |
| HT4203 | .109” x 6” x 9” | 25/bag | 40 bags/case |
| HT4208 | .109” x 8” x 9” | 10/bag | 120 bags/case |
| HT4211 | .078” x 9” x 10” | 10/bag | 150 bags/case |
| HT4212 | .125” x 9” x 10” | 25/bag | 50 bags/case |
| HT4231 | .109” x 12” x 12” | 25/bag | 25 bags/case |
| HT4232 | .50” x 2” x 3” | 24/bag | 50 bags/case |
| HT4233 | .25” x 3” x 3” | 100/bag | 10 bags/case |
| HT4234 | .375” x 3” x 4” | 100/bag | 10 bags/case |
| HT4236 | .109” x 3” x 5” | 100/bag | 10 bags/case |
| HT4266 | .109” x 6” x 6” | 25/bag | 100 bags/case |