| Click Here for Printer Friendly Version |
cleaning critical surfaces
MiraWIPE®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description |
MiraWIPE® is constructed from a continuous filament micro denier polyester, super soft textile resulting in enhanced absorbency and contamination pickup versus traditional polyester wipers. Woven from a no-run, no-stretch textile to minimize In-Use Particles from the face and edge of the wiper. Cleanroom washed and packed, MiraWIPE® is available in configurations to meet Class 1-1000 applications.
| Advantages |
| Unsurpassed cleaning efficiency. By using unique woven fiber construction, particle and organic pickup from glass, plastic, metal, ceramic and metal to metal surfaces is dramatically enhanced. | |
| Reduces cleaning time. Designed to improve particle removal from textured and porous ceramic, anodized aluminum and stainless steel surfaces. | |
| Delivers cleaner tools. No-Stretch woven construction leads to less abrasion generated particle generation and increased edge integrity during wiping. | |
| Extremely low particle, extractable, and Ionic levels. | |
| Titanium-free for advanced wafer fab cleaning applications and available with true sealed edge. | |
| First microfiber wiper compatible with Class 1 clean room. |
| Applications |
| Ideal wiper to clean monomer off CD/DVD mirror blocks. | |
| Engineered to clean trace residues and contamination from Vacuum Chambers so as to minimize tool downtime. | |
| Ideal for cleaning scratch sensitive surfaces such as plastics, optics, and Electro Static Chucks. | |
| Excellent general purpose cleanroom wiper for Semiconductor, Medical Device and Hard Disk Drive manufacturers. |

Heat Sealed Edge-HT5790

Wide Sealed Edge - HT5790S
| Part Numbers |
Part No. |
Processed |
Packaging
Style |
Edge |
HT5711 |
Class 100 |
Flat pack, 25 Bag, 50 Bags/Cs |
Heat sealed |
HT5711S |
Class 10 |
Flat pack, 25 Bag, 50 Bags/Cs |
Wide seal |
HT5711S-10ST |
Class 10 |
Flat pack, 10 Bag, 10 Bags/Cs |
Wide seal, Sterile |
HT5711S-25ST |
Class 10 |
Flat pack, 25 Bag, 50 Bags/Cs |
Wide seal, Sterile |
HT5711 Series are 11 ” x 11 ”. |
|||
HT5790S |
Class 10 |
Flat pack, 150 Bag, 8 Bags/Cs |
Wide seal |
HT5790 |
Class 100 |
Flat pack, 150 Bag, 8 Bags/Cs |
Heat sealed |
HT5790 Series are 9” x 9" |
|||
| Cleanliness |
HT5711 HT5790 |
HT5711S |
|
||||||
| Particle Generation via Biaxial Shake LPC test | ||||||||
| Particles ≥.5µm/cm2 | 2400 |
1200 |
||||||
| Extractables via Ion Chromatography PPM | ||||||||
| Anions | ||||||||
| Bromide | <.01 |
|||||||
| Chloride | .0094 |
- |
||||||
| Fluoride | .0218 |
<0.5 |
||||||
| Nitrate | .0218 |
<1 |
||||||
| Nitrite | .0218 |
<1 |
||||||
| Phosphate | .0218 |
<1 |
||||||
| Sulfate | <.06 |
<1 |
||||||
| Cations | ||||||||
| Ammonium | <.001 |
- |
||||||
| Calcium | <14 |
<.3 |
||||||
| Lithium | <1 |
- |
||||||
| Magnesium | <2 |
<.05 |
||||||
| Potassium | <13 |
<.2 |
||||||
| Sodium | <3 |
<20 |
||||||
| Titanium | <.01 |
|||||||
| Non-Volatile Residue | ||||||||
| DI Water | <.1 g/m2 | |||||||
| IPA | <.185 g/m2 | |||||||
| Absorptive Capacity |
| Basis Weight | 128 g/m2 | |
| Extrinsic Absorbency | 286 ml/m2 | |
| Intrinsic Absorbency | 2.22 ml/g | |
| Absorptive Rate | < 1 second |