Wiping non-viable particles is traditionally a high cost, time consuming operation that consumes significant quantities of labor, WIFI, Sterile Alcohol and wipers.
Wiping Non-Viable Particles
Non-Viable Particles are reduced by MiraWIPE®'s woven, non-stretch, polyester/nylon microfiber construction
Wiping non-viable particles just became much less expensive as MiraWIPE® cleans much more quickly with less use of WFI and Sterile Alcohol.
Non-viable particle particle cleaning just became much less time consuming as MiraWIPE® cleans surfaces more efficiently, eliminating costly recleaning.
Wiping ISO Class 5 clean rooms requires a wiper that quickly removes disinfectant residues that lead to non-viable particle excursions. MiraWIPE® through a unique micro fiber construction with a sealed edge perimeter bridges this gap by enabling excellent pick up and entrapment of the most stubbornly adhered residues while minimizing abrasion related fiber generation.
Poor Abrasion Resistance of Traditional Polyester Wipers
Can Lead to Non-Viable Particle Excursions

Surface Condition of Wipers with Sterile Alcohol
Standard Polyester wiper after wiping stainless steel surface
MiraWIPE® after wiping stainless steel surface
MiraWIPE's Abrasion Resistant Fabric Reduces
Non-Viable Particle Alerts as Indicated by the Data
ISO Class 5 fill line surfaces monitored using a Q3 Surface Particle Counter:
- MiraWIPE® removes 98.8% of non-viable particles at 0.5 µm
- Polyester Wiper removes 98.8% of non-viable particles at 0.5 µm
Stopper Bowl 1 - Z |
Conveyor 1 - Z |
||||
| Baseline Non-Viable Particle Readings |
.5 µm | 5 µm | Baseline Non-Viable Particle Readings |
.5 µm | 5 µm |
| Baseline - 1A | 15.40 | 0.05 | Baseline - 1B | 4.73 | 0.03 |
| Baseline - 2A | 2.12 | 0 | Baseline - 2B | 185.41 | 0.21 |
| Baseline - 3A | 12.87 | 0 | Baseline - 3B | 9.20 | 0.05 |
| Baseline - 4A | 2.43 | 0 | Baseline - 4B | 2.22 | 0 |
| Baseline - 5A | 29.06 | 0.03 | Baseline - 5B | 5.37 | 0.03 |
| Baseline - 6A | 7.36 | 0 | Baseline - 6B | 22.76 | 0 |
| Baseline Average Total | 11.54 | 0.008 | Baseline Average Total | 38.28 | 0.0533 |
| Post Polyester Wipe Particle Readings |
.5 µm | 5 µm | Post MiraWIPE® Particle Readings |
.5 µm | 5 µm |
| Post Polyester Wiper - 1A | 0.03 | 0 | Post MiraWIPE® - 1B | 0.05 | 0 |
| Post Polyester Wiper - 2A | 3.02 | 0 | Post MiraWIPE® - 2B | 0 | 0 |
| Post Polyester Wiper - 3A | 3.10 | 0 | Post MiraWIPE® - 3B | 0 | 0 |
| Post Polyester Wiper - 4A | 0.03 | 0 | Post MiraWIPE® - 4B | 0.21 | 0 |
| Post Polyester Wiper - 5A | 2.40 | 0 | Post MiraWIPE® - 5B | 0 | 0 |
| Post Polyester Wiper - 6A | 1.42 | 0 | Post MiraWIPE® - 6B | 0.21 | 0 |
| Post Polyester Wiper Average Total |
1.66 | 0 | Post MiraWIPE® Average Total |
0.47 | 0 |
| % Non-Viable Particle Reduction | 85.6% | 100% | % Non-Viable Particle Reduction | 98.8% | 100% |
Non-Viable Particle Comparison in an ISO Class 5 Biological Safety Cabinet
| Using Blacklight Technology | |
Polyester Wiper |
MiraWIPE® |
| Visible non-viable particles contributed by polyester wipers to the stainless steel surface |
MiraWIPE® removed non-viable particles, leaving the stainless steel surface clean |