Home > Industries > Sterile Processing > Wiping Non Viable Particles

Wiping non-viable particles is traditionally a high cost, time consuming operation that consumes significant quantities of labor, WIFI, Sterile Alcohol and wipers.

Wiping Non-Viable Particles

Non-Viable Particles are reduced by MiraWIPE®'s woven, non-stretch, polyester/nylon microfiber construction

Wiping non-viable particles just became much less expensive as MiraWIPE® cleans much more quickly with less use of WFI and Sterile Alcohol.

Non-viable particle particle cleaning just became much less time consuming as MiraWIPE® cleans surfaces more efficiently, eliminating costly recleaning.

Wiping ISO Class 5 clean rooms requires a wiper that quickly removes disinfectant residues that lead to non-viable particle excursions. MiraWIPE® through a unique micro fiber construction with a sealed edge perimeter bridges this gap by enabling excellent pick up and entrapment of the most stubbornly adhered residues while minimizing abrasion related fiber generation.

Poor Abrasion Resistance of Traditional Polyester Wipers
Can Lead to Non-Viable Particle Excursions

Non-Viable Particles from Polyester Fiber Abrasion
Surface Condition of Wipers with Sterile Alcohol

 

 

Standard Polyester wiper after wiping stainless steel surface

 

 

 

MiraWIPE® after wiping stainless steel surface


MiraWIPE's Abrasion Resistant Fabric Reduces
Non-Viable Particle Alerts as Indicated by the Data

ISO Class 5 fill line surfaces monitored using a Q3 Surface Particle Counter:

  • MiraWIPE® removes 98.8% of non-viable particles at 0.5 µm
  • Polyester Wiper removes 98.8% of non-viable particles at 0.5 µm

Stopper Bowl 1 - Z

Conveyor 1 - Z

Baseline Non-Viable
Particle Readings
.5 µm 5 µm Baseline Non-Viable
Particle Readings
.5 µm 5 µm
Baseline - 1A 15.40 0.05 Baseline - 1B 4.73 0.03
Baseline - 2A 2.12 0 Baseline - 2B 185.41 0.21
Baseline - 3A 12.87 0 Baseline - 3B 9.20 0.05
Baseline - 4A 2.43 0 Baseline - 4B 2.22 0
Baseline - 5A 29.06 0.03 Baseline - 5B 5.37 0.03
Baseline - 6A 7.36 0 Baseline - 6B 22.76 0
Baseline Average Total 11.54 0.008 Baseline Average Total 38.28 0.0533
 
Post Polyester Wipe
Particle Readings
.5 µm 5 µm Post MiraWIPE®
Particle Readings
.5 µm 5 µm
Post Polyester Wiper - 1A 0.03 0 Post MiraWIPE® - 1B 0.05 0
Post Polyester Wiper - 2A 3.02 0 Post MiraWIPE® - 2B 0 0
Post Polyester Wiper - 3A 3.10 0 Post MiraWIPE® - 3B 0 0
Post Polyester Wiper - 4A 0.03 0 Post MiraWIPE® - 4B 0.21 0
Post Polyester Wiper - 5A 2.40 0 Post MiraWIPE® - 5B 0 0
Post Polyester Wiper - 6A 1.42 0 Post MiraWIPE® - 6B 0.21 0
Post Polyester Wiper
Average Total
1.66 0 Post MiraWIPE®
Average Total
0.47 0
% Non-Viable Particle Reduction 85.6% 100% % Non-Viable Particle Reduction 98.8% 100%

Non-Viable Particle Comparison in an ISO Class 5 Biological Safety Cabinet

Using Blacklight Technology

Polyester Wiper
Non-Viable Particles under blacklight

MiraWIPE®
MiraWIPE doesn't leave behind Non-Viable Particles

Visible non-viable particles contributed by
polyester wipers to the stainless steel surface
MiraWIPE® removed non-viable particles,
leaving the stainless steel surface clean