At Foamtec, we help pharmaceutical manufacturers remove stubborn product residues thoroughly while protecting equipment surfaces and controlling contamination from cleaning tools.
During oral solid dose (OSD) changeovers, compacted powders, dried binders, sticky excipients, and residual films can make equipment cleaning slow and difficult. Feed frames, hoppers, tablet press components, granulator parts, and coating equipment each present different combinations of residue, surface finish, and cleaning access.
We match the cleaning tool to the task: loosen adhered deposits, collect the contamination, and complete the cleaning process using a repeatable method.
Start with the Residue and Equipment Surface
Before recommending a cleaning tool, we want to understand what your team is removing and where it accumulates.
Is the residue loose powder, a compacted deposit, a sticky film, or contamination trapped in a recess? Is the surface stainless steel, a coated component, a plastic guard, or precision tablet tooling?
Tablet press punches and dies should not automatically be treated as 316L stainless steel components. Their materials, coatings, and finishes require cleaning methods consistent with the tooling manufacturer’s instructions.
We also consider your detergent, concentration, operating temperature, contact time, and containment requirements. These details help us recommend products for your cleaning process.
Match the Cleaning Action to the OSD Residue
|
Cleaning challenge |
Our recommended approach |
Foamtec products |
|
Loose powder remaining after bulk removal |
Collect residual contamination with controlled wiping |
MiraWIPE® |
|
Heavy, compacted or caked deposits |
Break up hardened material for collection by vacuuming and wiping |
ScrubCLEAN® FS206 |
|
Hardened API, excipient deposits, or sticky films |
Scrub adhered residues while protecting the equipment surface |
Sahara® Wipers |
|
Contoured components and recessed features |
Use a cushioned cleaning format that follows component geometry |
PilloWIPE® FS4233 |
|
Final residue pickup and wiped rinsing |
Collect remaining contamination with fresh wiping surfaces |
MiraWIPE® |
|
Adhered powder on room surfaces |
Loosen deposits, vacuum the released material, then damp clean |
PharmaMOP® GO with Sahara+ heads |
Remove Compacted Deposits with ScrubCLEAN FS206
Heavy powder deposits can become compacted against equipment surfaces during production. Introducing liquid before removing this material can create a paste that spreads and increases the burden on subsequent cleaning steps.
We recommend ScrubCLEAN FS206 to fracture and loosen hardened deposits so the approved vacuum and wiping steps can collect them.
FS206 will not scratch stainless steel, including 316L, regardless of wiping direction or scrubbing action. Operators can use the motion needed to reach and break up the deposit without a prescribed wiping pattern to prevent scratching the stainless steel.
Its plastic-based scrubbing surface provides mechanical cleaning action without relying on conventional abrasive-coated fibers. This makes FS206 useful for caked API and excipient residues that ordinary wiping struggles to remove.
After loosening the deposits, collect the released material using the facility’s approved vacuum equipment and follow with MiraWIPE. Perform dry residue removal under the site’s containment controls, particularly when handling potent compounds.
Use Sahara and PilloWIPE for Adhered Residues
Our Sahara fine-pore polyurethane foam uses triangular-shaped struts to provide scrubbing action against hardened and sticky deposits. We designed it to remove stubborn residues while protecting sensitive equipment surfaces.
For OSD applications, Sahara helps remove adhered API and excipient residues from tablet press components and other process-equipment surfaces.
For components with contours and recessed features, PilloWIPE FS4233 combines a cushioned foam core with a scrubbing fabric over MiraWIPE. This construction helps maintain contact with irregular surfaces. Our application experience includes use on soft plastics and Perspex windows and shields without scratching.
We help customers select the cleaning format for each component and check compatibility with their detergent formulation, temperature, and exposure time.
Collect Loosened Contamination with Fresh MiraWIPE
Loosening a deposit is only part of cleaning. The removed material must also be collected and carried away.
We use MiraWIPE microfiber wipers for residue collection and final wiping within the approved process. Their microfiber structure helps dislodge, entrap, and remove contamination. Their durable fabric and sealed edges help control particle and fiber release during equipment cleaning.
Where the procedure includes a wiped rinse, use fresh material. A wiper loaded with detergent and product residue should not carry that contamination into the next step.
Define how frequently operators expose a fresh wiping face and when the wiper must be replaced to prevent redistribution of collected material.
Select the MiraWIPE Grade for Your Application
Our website identifies the following cleanroom compatibility:
|
MiraWIPE family |
Example part number |
Website ISO classification |
|
MiraWIPE S |
HT5790S |
ISO Class 3–5 |
|
MiraWIPE SM |
HT5790SM |
ISO Class 5 |
|
MiraWIPE SN |
HT5790SN |
ISO Class 7 |
|
MiraWIPE SNN |
HT5790SNN |
ISO Class 8 |
We use room classification as one selection factor. Direct product contact, residue characteristics, surface condition, particulate requirements, and cleaning chemistry also matter.
Sterile configurations are available where required. We provide current product information and lot-specific Certificates of Conformance and Analysis to support your evaluation.
Make Final Wiping and Drying Process-Specific
We do not prescribe a universal 70% IPA wipe for every OSD changeover.
Your approved cleaning process determines the rinse, final wiping, drying, and disinfection requirements. Where IPA is specified, use the selected wiper and defined application method. An IPA wipe does not replace effective removal of API, excipient, or detergent residues.
After cleaning, protect components from recontamination during handling and storage. Include drying requirements and clean hold times in the procedure.
Include Room Surfaces in the Changeover Plan
Equipment cleaning and room cleaning need coordinated procedures.
For OSD room surfaces with adhered powder, we recommend PharmaMOP GO with Sahara+ heads. The Sahara strips loosen deposits so suitable HEPA-filtered vacuum equipment can collect them. A fresh head then performs the approved damp-cleaning step.
This approach helps address compacted material that ordinary mopping leaves behind. Perform the sequence under the facility’s containment controls, with cleaned equipment protected from room-cleaning activities.
Our PharmaMOP GO system also allows operators to change and discard heads without manually handling the soiled cleaning surface.
Build Repeatability into the Cleaning Procedure
We recommend documenting more than the product name. A useful procedure defines:
- The cleaning tool and part number for each component and step.
- Detergent concentration, temperature, and contact time.
- Cleaning sequence, residue-collection method, and tool replacement criteria.
- Dirty hold time and maximum campaign conditions.
- Rinsing, drying, inspection, and sampling requirements.
- Clean-part protection, storage, and clean hold time.
These controls help make residue removal consistent between operators and shifts. Changes to products or methods should be evaluated through the site’s change-control process.
Verify Cleanliness Against Your Approved Criteria
We view visual inspection as an essential part of a broader cleaning-control program.
Inspect difficult locations as well as readily visible surfaces. Look for remaining deposits, fibers, unexplained haze, and changes in surface condition. Where recurring contamination appears, investigate the cleaning tools and method alongside operator technique.
Cleaning validation generally requires evidence beyond visual appearance. Routine changeover testing and release should follow the site’s approved program and documented risk assessment. Supplementary inspection tools can help investigate contamination, but they do not independently demonstrate compliance with API or detergent residue limits.
Tell Us What Is Slowing Your OSD Changeover
Are your operators struggling with caked powder, hardened films, repeated wiping, or difficult-to-reach deposits? Are you finding fibers after cleaning or damage from your current scrubbing tools?
We can help you select products for the specific problem—from FS206 for breaking up hardened deposits without scratching stainless steel, to Sahara for adhered residues, MiraWIPE for contamination pickup, and PharmaMOP GO for room surfaces.
Share the component, surface material, residue, cleaning chemistry, and step causing difficulty. We will help identify suitable products and provide technical documentation to support your evaluation.
Contact Foamtec for an OSD cleaning application review, or call (760) 599-7160.
Technical references: 21 CFR 211.67—Equipment Cleaning and Maintenance; EU GMP Annex 15—Qualification and Validation; EMA GMP Questions and Answers.